  relays high capacity 50 amp mini relays standard mini relays micro relays p ower relays connector modules c h i e f e n t e r pr is es i n c . m a s t e r i n t e r n a t i o n a l d i s t r i b u t o r http://www..net/ datasheet pdf - http://www..net/
m as t e r i n t e r n a tio n a l di s t r ib u t or v i s i t o u r w e b s i t e f o r o t h e r a v a i l a b l e b o s c h p r o d u c t s d c m o t o r s h o r n s w i p e r s y s t e m s a n d a c c e s s o r i e s r e l a y s w w w . c h i e f e n t . c o m 8 0 0 . 8 3 1 . 7 2 9 4 http://www..net/ datasheet pdf - http://www..net/
relay applications 4 t he application process 5 explanatory notes 6 operating modes 7 high capacity 50 amp mini relays 8 standard mini relays 10 micro relays 12 p ower relays 14 connector modules 16 t able of contents 3 http://www..net/ datasheet pdf - http://www..net/
a pplication notes relay applications b osch relays were originally designed for use in automotive applications. the great range of different versions are used in the most varied applications. o w iper motors o fan motors o starting motors o cooling fans o rear defrosters o brake lamps o headlamps o electric seat adjustment o electric seat heating o electric window mirrors o fuel pumps o horn o central locking o security systems o many other uses in addition to these purely automotive applications, bosch relays are ideal for switching 12v or 24v components. this is true for both mobile and stationary applications, where for example, electric motors are actuated. with these relays, a multiplicity of drive assignments can be implemented. b osch relays are employed in o automatic sliding doors o devices for the disabled o b oat electric devices o electric lawn mowers o material handling technology o garage door drives o control cabinets o v ending machines o b attery chargers o emergency generators o agricultural equipment o furniture adjustments o cleaning devices o robot controls o t oys 4 applications http://www..net/ datasheet pdf - http://www..net/
t he application process consideration of the following questions will aid in the selection of the proper relay to suit your application. 1. t ype of load? (resistive, motor, lamp, inductive) 2. size of load? w hat is the number of amps being switched o n, carried during steady state performance, and being switched of f? 3. t ime?urrent curve? f or a motor or lamp load, what are the magnitude and duration of the in rush peak current during turn o n? 5 applications negative drop out voltage spike when the coil is de-energized? (this protects other devices in your circuit.) 9. method of mounting? w ill the relay be plugged into a power distribution center, or be mounted via a bracket? 10. are other devices required? w ill you require mounting connector modules and their related terminals? contact chief enterprises, inc. for help in optimizing your relay application. 4. multi-tasking? w ill one relay part number a ?switch a lamp for example in one circuit, and a second relay part number a switch a resistive load in another circuit? 5. duty cycle? w hat is the expected o n (running) time for your load, and the expected o ff (resting) time? 6. t emperature conditions? w hat are the minimum and maximum storage and operating temperatures the relay will experience? 7. relay life? how many switching cycles are required? 8. coil suppression? w ill a resistor or diode in parallel to the coil be required to suppress a p ermissible continuous current (appr o ximate values) metric size sae w ire size amps, amps, mm 2 gauge at 25? at 50? 1 0.5 20 1 12 1 8.0 1 0.8 18 1 16 10.6 1 1.0 16 1 20 13.3 1 2.0 14 1 30 19.6 1 3.0 12 1 34 22.6 1 5.0 10 1 51 34.0 1 8.0 1 8 1 68 45.0 13.0 1 6 1 91 60.5 19.0 1 4 121 80.0 recommended wire sizes for all relays operating voltage temperature correction factors for all relays for ambient temperature (?) ?0 ?0 0 +23 +40 +60 +80 +100 multiply table value by 0.75 0.83 0.91 1.00 1.07 1.15 1.23 1.31 cycle life values for all relays are based on actual endurance tests performed by b osch on a continuing basis. the cycle life expectancy may differ in your appli - cation. the values listed are reflective of customer requirements, and should only be used as a guide. t hese values are to be used only as a guide. http://www..net/ datasheet pdf - http://www..net/
explanatory notes on parameters 6 relays overview relay applications t his catalog contains the technical information which a design engineer requires in order to select a relay for his particular requirements. bosc h d c relays were originally designed for automotive applications. we recommend prior technical clarification for all other applications, especially where requirements, loading or ambient conditions differ from those applying to automotive applications. b osch dc relays are able to withstand exposure to extreme conditions and must comply with the following requirements: t hey must switch high powers function efficiently and reliably in a broad temperature range be extremely resistant to vibration have a long service life, and be highly climate-proof. b osch dc relays are used to switch electrical devices featuring high power levels or which are sensitive to voltage loss. relays relieve the load on control switches and make for small voltage drops with economical conductor cross- sections. and relays make simple interlock circuits possible. micro-relay 1 cap, 2 magnet bracket and term. 3, 3 coil, 4 bobbin, 5 armature, 6 b aseplate, 7 damping resistor or diode, 8 connecting wire, 9 core, 10 term. 1/2, 11 contact, 12 spring, 13 term. 4, 14 term. 5. mini-relay 1 baseplate, 2 term. 86, 3 term. 87 , 4 term. 87a, 5 term. 85, 6 clamping piece, 7 coil connection bracket, 8 term. 3 0, 9 magnet bracket, 10 cap, 11 coil, 12 b obbin, 13 core, 14 armature, 15 spring, 16 contact. mini-relays and micro-relays are ideal for use where the available space is restricted. multiple connectors, together with pre-tested wiring harnesses, ensure simple assembly and the lowest possible error rate. this applies in particular to o e m, but also to customer service. the following versions of mini-relays and micro-relays are available: relays without mounting bracket. easily plugged into buttable socket housings for screwing to mounting surface. relays with mounting bracket. connected using a 5-pole socket housing. relays with solder terminals for soldering into pc boards. p ower relays can switch a nominal current of 50 a and more, and are suitable for switching motors, starting motors and other devices. http://www..net/ datasheet pdf - http://www..net/
switching operations response is the operation by which a relay is switched from its normal position to its operat- ed position. opening is an operation whic h results in the electrical contact being opened. release (dropout) is the operation by which a relay is switched from its operated position to its normal position. a switching cycle comprises the single response and release of a relay . t he number of switching operations comprises the total number of switching cycles. closing is an operation whic h results in contact closure. relays 7 operating modes w ith inductive loads and motors, a suppressor circuit, which can be set up parallel to the load with a free-wheeling diode, is required (see circuit). l inductive load, d free-wheeling diode, u supply voltage http://www..net/ datasheet pdf - http://www..net/
8 relays p art pull -i n drop-out resi stance nominal number v ol tage v ol tage no resistor , w ith operating or with diode r esistor current 0 332 019 103 8.0 v 1.2 ?5.0 v 75 ?5 ohm 160 ma 0 332 019 110 8.0 v 1.2 ?5.0 v 75 ?5 ohm 160 ma 0 332 209 137 8.0 v 1.2 ?5.0 v 75 ?5 ohm 160 ma 0 332 209 138 8.0 v 1.2 ?5.0 v 75 ?5 ohm 160 ma 0 332 019 203 16.0 v 2.4 ?10.0 v 255 ?15 ohm 95 ma 0 332 209 203 16.0 v 2.4 ?10.0 v 255 ?15 ohm 95 ma 0 332 209 204 16.0 v 2.4 ?10.0 v 255 ?15 ohm 95 ma 0 332 209 211 16.0 v 2.4 ?10.0 v 255 ?15 ohm 95 ma resi stive l o ad mo t or l o ad lamp l o ad in ductive l o ad lo ad v ol tage c ont act in rush/ continuous/ g rou p p osition continuous life cycles continuous life cycles continuous life cycles inductivity life cycles 50a 150,000 90/40a 150,000 30a 150,000 1 12v no 40a 250,000 75/30a 250,000 20a 250,000 n/a n/a 30a 500,000 50/20a 300,000 10a 500,000 50a 150,000 90/40a 150,000 30a 150,000 no 40a 250,000 75/30a 250,000 20a 250,000 n/a n/a 2 12v 30a 500,000 50/20a 300,000 10a 500,000 20a 100,000 35/15a 75,000 15a 50,000 nc 15a 150,000 25/10a 150,000 10a 50,000 n/a n/a 10a 300,000 15/5a 300,000 5a 600,000 3 24v no 20a 250,000 40/16a 250,000 16a 250,000 16a/4mh 100,000 4 24v no 20a 250,000 40/16a 250,000 16a 250,000 n/a n/a nc 10a 250,000 n/a n/a 5a 150,000 n/a n/a lo ad and l if e c y cle test d at a for high cap a city m in i r e la ys contact testing conditions t est temp. relay type l oad switching cycle for sto (silver tin oxide) contacts: life cycles tested at 85?, 13.5v (27v for 24v relays) lamp 1 sec on, 9 sec off 85? high capacity resistive 2 sec on, 2 sec off motor 5 sec on, 5 sec off h igh cap a city m in i r e lay l o ad tab le op e rating chara c te ri stics m echanical chara c te ri stics e nviron me ntal chara c te ri stics response time 10 ms random vibration test 10 hz ?000hz for 4 h operating temperature ?0? to +85? response time, with diode 15 ms sine wave vibration test 10 hz ?00hz, 2.5 g? for 4 h humidity test 95% for 7 days contact voltage drop - new, at 10a 50 mv drop test ?all sides 1 meter s alt spray test?ll sides 144 hours (12 v, at 10 a) - after life test 80 mv t erminal retention force > 110 n dust test 8 hours (24 v, at 10 a) - after life test 100 mv cover retention force > 220 n mechanical life > 1,000,000 cover crush force > 220 n coil inductance 250 mh high capacity 50 amp mini relays all are dust proof; all 12v relays have a resistor in parallel to the coil to limit e mi p art descr i ption illustration and t erminal v ol tage c ont act max imu m n.o. o th e r l o ads: number and details dimensions, diagram; operating voltage mate r ial resi stive l o ad see group # # 4 terminal relay drawing circuit diag. nominal ?max. t 8 7 amps ?life cycles in l o ad tab le 0 332 019 103 spst , resistor, # a a 3 s 7 12v ? 15v sto 5 0a ? 150,000 1 0 332 019 110 spst , resistor, bracket, # b a 3 s 7 12v ? 15v sto 5 0a ? 150,000 1 0 332 209 13 7 spdt , resistor a a 2 s 5 12v ? 15v sto 5 0a ? 150,000 2 0 332 209 13 8 spdt , resistor, bracket b a 2 s 5 12v ? 15v sto 5 0a ? 150,000 2 0 332 019 203 spst , bracket b a 1 s 1 24v ? 30v sto 20a ? 250,000 3 0 332 209 203 spdt , bracket b a 2 s 4 24v ? 30v sto 20a ? 250,000 4 0 332 209 20 4 spdt , diode p a a 2 s 6 24v ? 30v sto 20a ? 250,000 4 0 332 209 211 spdt a a 2 s 4 24v ? 30v sto 20a ? 250,000 4 http://www..net/ datasheet pdf - http://www..net/
relays 9 illustrations and dimension drawings blade terminal size: 6.3 x 0.8 mm to t erminal di n 4 6 244 (similar to i s o 8 0 92) configuration t erminal diagrams circuit diagrams a b http://www..net/ datasheet pdf - http://www..net/
10 relays p art descr i ption illustration and t erminal v ol tage c ont act max imu m n.o. o th e r l o ads: number and details dimensions, diagram; nominal ?max. mate r ial resi stive l o ad see group # ## double 87 terminal drawing circuit diag. operating voltage t 8 7 amps ?life cycles in l o ad tab le 0 332 019 150 spst, bracket, ## a a 1 s 1 12v ? 15v hard silver 40a ? 200,000 6 0 332 019 151 spst, ## a a 1 s 1 12v ? 15v hard silver 40a ? 200,000 6 0 332 019 155 spst, diode, bracket, ## b a 1 s 2 12v ? 15v hard silver 40a ? 200,000 5 0 332 209 150 spdt, bracket b a 2 s 4 12v ? 15v hard silver 40a ? 200,000 7 0 332 209 151 spdt a a 2 s 4 12v ? 15v hard silver 40a ? 200,000 7 0 332 209 159 spdt, resistor a a 2 s 5 12v ? 15v hard silver 40a ? 200,000 7 0 332 209 161 spdt, resistor, bracket b a 2 s 5 12v ? 15v hard silver 40a ? 200,000 7 0 332 209 167 spdt, resistor p a a 2 s 5 12v ? 15v silver nickel 30a ? 250,000 8 0 332 209 168 spdt p a a 2 s 4 12v ? 15v hard silver 30a ? 250,000 8 p = plated terminals p art pull -i n drop-out resi stance nominal number v ol tage v ol tage no resistor , w ith operating or with diode r esistor current 0 332 019 150 8.0 v 1.0 ?5.0 v 85 ?5 ohm 140 ma 0 332 019 151 8.0 v 1.0 ?5.0 v 85 ?5 ohm 140 ma 0 332 019 155 8.0 v 1.0 ?5.0 v 85 ?5 ohm 140 ma 0 332 209 150 8.0 v 1.0 ?5.0 v 85 ?5 ohm 140 ma 0 332 209 151 8.0 v 1.0 ?5.0 v 85 ?5 ohm 140 ma 0 332 209 159 8.0 v 1.0 ?5.0 v 75 ?5 ohm 160 ma 0 332 209 161 8.0 v 1.0 ?5.0 v 75 ?5 ohm 160 ma 0 332 209 167 8.0 v 1.2 ?5.5 v 75 ?5 ohm 160 ma 0 332 209 168 7.0 v 0.5 ?4.0 v 65 ?5 ohm 184 ma lo ad and l if e c y cle test d at a for stan d ard m in i r e la ys contact testing conditions t est temp. relay type l oad switching cycle for sto (silver tin oxide) contacts: life cycles tested at 23?, 13.5v lamp 2 sec on, 2 sec off for hard silver (agcu2ni) contacts: life cycles tested at 23?, 13.5v 23? standard resistive 2 sec on, 2 sec off for silver nickel (agni20) contacts: life cycles tested at 23?, 13.5v motor 2 sec on, 2 sec off resi stive l o ad mo t or l o ad lamp l o ad in ductive l o ad lo ad v ol tage c ont act in rush/ continuous/ g rou p p osition continuous life cycles continuous life cycles continuous life cycles inductivity life cycles 40a 200,000 30a 100,000 5 12v no 30a 300,000 50/25a 100,000 20a 200,000 15a/8mh 50,000 10a 500,000 10a 500,000 40a 200,000 30a 100,000 6 12v no 30a 300,000 50/25a 100,000 20a 200,000 24a/2mh 100,000 10a 500,000 10a 500,000 40a 200,000 30a 100,000 7 12v no 30a 300,000 50/25a 100,000 20a 200,000 24a/8mh 100,000 10a 500,000 10a 500,000 nc 20a 250,000 n/a n/a 10a 100,000 15a/8mh 100,000 30a 250,000 30a 100,000 8 12v no 20a 300,000 75/30a 100,000 20a 200,000 24a/8mh 100,000 10a 500,000 10a 500,000 nc 20a 250,000 n/a n/a 10a 100,000 15a/8mh 100,000 stan d ard m in i r e lay l o ad tab le op e rating chara c te ri stics m echanical chara c te ri stics e nviron me ntal chara c te ri stics response time 10 ms random vibration test 10 hz ?000hz for 4 h operating temperature ?0? to +85? response time, with diode 15 ms sine wave vibration test 10 hz ?00hz, 2.5 g? for 4 h humidity test 95% for 7 days contact voltage drop - new, at 10a 50 mv drop test ?all sides 1 meter s alt spray test?ll sides 144 hours (12 v, at 10 a) - after life test 80 mv t erminal retention force > 110 n dust test 8 hours (24 v, at 10 a) - after life test 100 mv cover retention force > 220 n mechanical life > 1,000,000 cover crush force > 220 n coil inductance 250 mh standard mini relays http://www..net/ datasheet pdf - http://www..net/
relays 11 illustrations and dimension drawings blade terminal size: 6.3 x 0.8 mm to t erminal di n 4 6 244 (similar to i s o 8 0 92) configuration t erminal diagrams circuit diagrams recommended polarity t erm. 86 + * s3 available on request t erm. 30 + a b http://www..net/ datasheet pdf - http://www..net/
12 relays p art descr i ption illustration and t erminal v ol tage c ont act max imu m n.o. o th e r l o ads: number and details dimensions, diagram; operating voltage mate r ial resi stive l o ad see group # p = plated terminals drawing circuit diag. nominal ?max. t 8 7 amps ?life cycles in l o ad tab le 0 332 017 300 spst, resistor p a a 1 s 1 12v ? 16v sto 20a ? 300,000 9 0 332 017 302 spst, resistor, bracket p b a 1 s 1 12v ? 16v sto 20a ? 300,000 9 0 332 207 307 spdt, resistor p a a 2 s 2 12v ? 16v sto 20a ? 300,000 11 0 332 207 310 spdt, resistor, bracket p b a 2 s 2 12v ? 16v sto 20a ? 300,000 11 0 332 207 402 spdt, diode p a a 2 s 3 24v ? 30v sto 10a ? 250,000 12 0 332 207 404 spdt, resistor, bracket b a 2 s 2 24v ? 30v sto 10a ? 250,000 12 p = plated terminals p art pull -i n drop-out resi stance nominal number v ol tage v ol tage no resistor , w ith operating or with diode r esistor current 0 332 017 300 8.0 v 3 1.5 v 78 ?6 ohm 154 ma 0 332 017 302 8.0 v 3 1.5 v 78 ?6 ohm 154 ma 0 332 207 307 8.0 v 3 1.5 v 78 ?6 ohm 154 ma 0 332 207 310 8.0 v 3 1.5 v 78 ?6 ohm 154 ma 0 332 207 402 17.0 v 3 3.0 v 410 ?20 ohm 60 ma 0 332 207 404 17.0 v 3 3.0 v 335 ?20 ohm 72 ma lo ad and l if e c y cle test d at a for micro r e la ys contact testing conditions l oad switching cycle for sto (silver tin oxide) contacts: life cycles tested at 85?, 12v; 23? for 24v resistive 2 sec on, 2 sec off motor 5 sec on, 5 sec off for hard silver (agcu2ni) contacts: life cycles tested at 23?, 12v lamp 1 sec on, 9 sec off resi stive l o ad mo t or l o ad lamp l o ad in ductive l o ad lo ad v ol tage c ont act in rush/ continuous/ g rou p p osition continuous life cycles continuous life cycles continuous life cycles inductivity life cycles 9 12v no 20a 300,000 30/15a 200,000 20a 150,000 4a/4mh 300,000 10 12v no 20a 300,000 35/20a 100,000 n/a n/a n/a n/a nc 10a 300,000 n/a n/a n/a n/a n/a n/a 11 12v no 20a 300,000 30/15a 200,000 20a 150,000 4a/4mh 300,000 nc 10a 150,000 n/a n/a 10a 75,000 n/a n/a 12 24v no 10a 250,000 n/a n/a n/a n/a n/a n/a nc 5a 250,000 n/a n/a n/a n/a n/a n/a m icro r e lay l o ad tab le op e rating chara c te ri stics m echanical chara c te ri stics e nviron me ntal chara c te ri stics response time 10 ms random vibration test 10 hz?000hz for 4 h operating temperature ?0? to +100 c (12v) response time, with diode 15 ms sine wave vibration test 10 hz?00hz, 2.5 g? for 3 h ?0? to +85? (24v) contact voltage drop - new, at 10a 50 mv drop test ?all sides 1 meter humidity test 95% for 7 days - after life test 200 mv t erminal retention force > 110 n s alt spray test?ll sides 4 8 hours mechanical life > 1,000,000 cover retention force > 220 n dust test 8 hours coil inductance 190mh (12v) cover crush force > 220 n 750mh (24v) micro relays http://www..net/ datasheet pdf - http://www..net/
relays 13 illustrations and dimension drawings t erminal diagrams circuit diagrams blade terminal size to d i n 46 244, similar to i s o 8 0 92: t erms. 1 and 2 (4): 4.8 x 0.8 mm; terms. 3 and 5: 6.3 x 0.8 mm blade terminal size to d i n 46 244, similar to i s o 8 0 92: t erms. 1 and 2 (4): 4.8 x 0.8 mm; terms. 3 and 5: 6.3 x 0.8 mm cross-reference of terminal designations micro-relay mini-relay p olarity 1 86 + 2 85 3 30 + 4 8 7a 5 87 n o contact changeover contact a b http://www..net/ datasheet pdf - http://www..net/
14 relays p art descr i ption illustration and t erminal v ol tage c ont act max imu m n.o. o th e r l o ads: number and details dimensions, diagram; operating voltage mate r ial resi stive l o ad see group # drawing circuit diag. nominal ?max. t 8 7 amps ?life cycles in l o ad tab le 0 332 002 15 0 spst , dual contact a s 6 12v ? 16v sto 75a ? 100,000 13 0 332 002 15 6 spst , with parallel and a s 3 12v ? 15v silver nickel 75a ? 100,000 14 series diodes 0 332 002 25 0 spst , pre?ontact a s 2 24v ? 32v silver nickel 5 0a ? 100,000 15 0 332 002 25 6 spst , with parallel and a s 3 24v ? 30v silver nickel 5 0a ? 100,000 16 p art pull -i n drop-out resi stance nominal number v ol tage v ol tage no resistor , w ith operating or with diode r esistor current 0 332 002 150 1 8.0 v 1.5 ?4.0 v 46 ?5 ohm n/a 290 ma 0 332 002 156 1 8.0 v 1.5 ?4.0 v 46 ?5 ohm n/a 290 ma 0 332 002 250 18.0 v 1.0 ?8.0 v 130 ?10 ohm n/a 200 ma 0 332 002 256 18.0 v 1.0 ?8.0 v 130 ?10 ohm n/a 200 ma lo ad and l if e c y cle test d at a for p owe r r e la ys contact testing conditions l oad switching cycle for sto (silver tin oxide) contacts: life cycles tested at 23? resistive 2 sec on, 2 sec off for silver nickel (agni20) contacts: life cycles tested at 23? motor 5 sec on, 5 sec off resi stive l o ad mo t or l o ad lo ad v ol tage c ont act g rou p p osition continuous life cycles in rush duration continuous life cycles 13 12v no 75a 100,000 400a 1 sec. 60a 40,000 14 12v no 75a 100,000 250a 1 sec. 60a 40,000 15 24v no 50a 100,000 200a 1 sec. 40a 40,000 16 24v no 50a 100,000 150a 1 sec. 40a 40,000 powe r r e lay l o ad tab le op e rating chara c te ri stics m echanical chara c te ri stics e nviron me ntal chara c te ri stics response time 15 ms random vibration test 10 hz ?000hz for 3 h operating temperature ?0? to +85? contact voltage drop - new, at 10a 100 mv sine wave vibration test 10 hz ?00hz, 2.5 g? for 3 h humidity test 95% for 14 days (24 v, at 10 a) - after life test 200 mv drop test ?all sides 1 meter s alt spray test?ll sides 144 hours mechanical life > 1,000,000 t erminal retention force > 110 n dust test 8 hours coil inductance 200 mh (12v) cover retention force > 300 n 500 mh (24v) cover crush force > 220 n p ower relays http://www..net/ datasheet pdf - http://www..net/
15 relays illustrations and dimension drawings circuit diagrams a accessories: t win socket housing for energizing side (terms. 85 and 86). order with amp number 180 9 07 p olarity: terms. 86 and 30 to + method of operation of leading contact 1. closure of leading contact coil energized; current flows in leading contact for a fraction of a second. 2. closure of main contact coil energized; current flows in main contact. the characteristics of the tungsten leading contact make it ideal for the considerable loads resulting from the separation arc when contacts are opening (inductive loads). the main contact ensures efficient current flow with minimum voltage losses. the tungsten leading contact (late-opening when the contacts open) ensures that the main contacts are not subject to separation arcs. http://www..net/ datasheet pdf - http://www..net/
16 plastic connector modules for relays illustrations and dimension drawings c on n ec t or modu le s for m in i r e la ys c on n ec t or modu le s for micro r e la ys module #3 334 4 8 5 00 8 (metric) 1 socket #3 334 4 8 5 00 7 (metric) 1 module #3 334 4 8 5 0 45 (metric) 1 t3, t5 (metric) 2 t1, t2, t4 socket #3 334 4 8 5 0 46 (metric) 1 t3, t5 (metric) 2 t1, t2, t4 1 t erminals: amp part: 42238-2 (loose piece), or 42100-2 (strip) 2 t erminals: mt s part: 26313.201.011 c h i e f e n t e r pr i s e s i n c . m a s t e r i n t e r n a t i o n a l d i s t r i b u t o r 922 n. oaklawn ave. ?elmhurst, il 60126-1018 t elephone:(800) 831- 7 294 ?fax: (630) 530-115 4 w ebsite: www.chiefent.com http://www..net/ datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of 0332002150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X